enow.com Web Search

  1. Ads

    related to: 2 hour fire rated panels exterior construction doors interior

Search results

  1. Results from the WOW.Com Content Network
  2. Smokeproof enclosure - Wikipedia

    en.wikipedia.org/wiki/Smokeproof_enclosure

    Under United States building codes, the stairwell of a smokeproof enclosure must have walls with a 2-hour fire resistance rating and vestibule doors (if provided) with a 1.5 hour fire resistance rating. [7]

  3. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.

  4. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops

  6. EN 16034 - Wikipedia

    en.wikipedia.org/wiki/EN_16034

    EN 16034 is a set of European standards which specify the technical performance characteristics for fire resistant and smoke control products, such as fire doors. Compliance with this standard requires to fulfill the requirements of the Construction Product Regulation [ 1 ] for construction products (short CPR).

  7. Building insulation material - Wikipedia

    en.wikipedia.org/wiki/Building_insulation_material

    [2] Depending on usage and building codes and environment, most foams require protection with a thermal barrier such as drywall on the interior of a house. For example, a 15-minute fire rating may be required. Can shrink slightly while curing if not applied on a substrate heated to the manufacturer's recommended temperature.

  1. Ads

    related to: 2 hour fire rated panels exterior construction doors interior