enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. List of referred Indian Standard Codes for civil engineers

    en.wikipedia.org/wiki/List_of_referred_Indian...

    A large number of Indian Standard (IS) codes are available that are meant for virtually every aspect of civil engineering one can think of. During one's professional life one normally uses only a handful of them depending on the nature of work they are involved in. Civil engineers engaged in construction activities of large projects usually have to refer to a good number of IS codes as such ...

  5. Waffle slab - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab

    The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.

  6. Formwork - Wikipedia

    en.wikipedia.org/wiki/Formwork

    Formwork tables in use at a building site with more complicated structural features. Crane fork or elevator handled: By this approach the tables are limited in size and weight. Typical widths are between 6 and 10 feet (1.8 and 3.0 m), typical lengths are between 12 and 20 feet (3.7 and 6.1 m), though table sizes may vary in size and form.

  7. List of GOST standards - Wikipedia

    en.wikipedia.org/wiki/List_of_GOST_standards

    GOST R 59488-2021: Automobile roads for general use. Bridge structures. Calculation rules for reinforcing reinforced concrete beam spans; GOST R 59769-2021: Medical products. Risk management. Guidance for planning the risk analysis and assessment process; GOST R 70033-2022: Earth Remote Sensing from Space. Data of Earth Remote Sensing from Space.

  8. Concrete cover - Wikipedia

    en.wikipedia.org/wiki/Concrete_cover

    Concrete cover, in reinforced concrete, is the least distance between the surface of embedded reinforcement and the outer surface of the concrete (ACI 130). The concrete cover depth can be measured with a cover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.

  9. Grade beam - Wikipedia

    en.wikipedia.org/wiki/Grade_beam

    Grade beam. A grade beam or grade beam footing is a component of a building's foundation. It consists of a reinforced concrete beam that transmits the load from a bearing wall into spaced foundations such as pile caps or caissons. [1] It is used in conditions where the surface soil's load-bearing capacity is less than the anticipated design loads.