European pipe is standardized to ISO 2531 and its descendent specifications EN 545 (potable water) and EN 598 (sewage). European pipes are sized to approximately match the internal diameter of the pipe, following internal lining, to the nominal diameter. ISO 2531 maintains dimensional compatibility with older German cast iron pipes.
In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
Ductile iron pressure pipes with socket with cement-mortar lining for gas and water pipelines; dimensions and masses: Withdrawn: DIN EN 545, DIN EN 969: EN 545, EN 969: DIN 28610-2: Ductile iron pressure pipes with socket for gas and water pipelines rated for pressures over 4 bar up to and including 16 bar; dimensions and masses: Withdrawn: DIN ...
The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [ 1 ] such as fire sprinkler systems , [ 2 ] water supply networks , and irrigation systems.
For pipe sizes of NPS 14 inch (DN 350) and greater the NPS size is the actual diameter in inches and the DN size is equal to NPS times 25 (not 25.4) rounded to a convenient multiple of 50. For example, NPS 14 has an OD of 14 inches or 355.60 millimetres, and is equivalent to DN 350.
The following table lists historical approximations to the Colebrook–White relation [23] for pressure-driven flow. Churchill equation [ 24 ] (1977) is the only equation that can be evaluated for very slow flow (Reynolds number < 1), but the Cheng (2008), [ 25 ] and Bellos et al. (2018) [ 8 ] equations also return an approximately correct ...
The branch lines may terminate in a dead end or may connect at each end to different (usually opposite) points on the looped main. In the latter case, less water supply pressure is required as the hydraulic pressure drop is lower in the branch pipe as water flows from both ends of the branch line to any sprinkler.
Cement-mortar lined ductile iron pipe is a ductile iron pipe with cement lining on the inside surface, and is commonly used for water distribution. Cement-mortar lined ductile iron pipe is governed by standards set forth by DIPRA ( Ductile Iron Pipe Research Association ), and was first used in 1922 in Charleston, South Carolina .