The van Deemter equation is a hyperbolic function that predicts that there is an optimum velocity at which there will be the minimum variance per unit column length and, thence, a maximum efficiency. The van Deemter equation was the result of the first application of rate theory to the chromatography elution process.
Jan Jozef van Deemter (31 March 1918 – 10 October 2004) was a Dutch physicist and engineer known for the Van Deemter equation in chromatography. [ 1 ] [ 2 ] [ 3 ] He obtained his doctorate in physics from the University of Amsterdam in June of 1950.
A faster flow rate of the eluent minimizes the time required to run a column and thereby minimizes diffusion, resulting in a better separation. However, the maximum flow rate is limited because a finite time is required for the analyte to equilibrate between the stationary phase and mobile phase, see Van Deemter's equation.
The parameters are largely derived from two sets of chromatographic theory: plate theory (as part of partition chromatography), and the rate theory of chromatography / Van Deemter equation. Of course, they can be put in practice through analysis of HPLC chromatograms, although rate theory is considered the more accurate theory.
A monolithic HPLC column, or monolithic column, is a column used in high-performance liquid chromatography (HPLC). The internal structure of the monolithic column is created in such a way that many channels form inside the column. The material inside the column which separates the channels can be porous and functionalized.
The same equation applies in chromatography processes as for the packed bed processes, namely: = In packed column chromatography, the HETP may also be calculated with the Van Deemter equation. In capillary column chromatography HETP is given by the Golay equation.
The sample is first subjected to analysis by HPLC and then is subjected to mass analysis. Different types of mass analyzers, ToF, qudrupole, etc., can be used in the MS. [ 5 ] Common solvents used in normal or reversed phase LC such as water, acetonitrile, and methanol are all compatible with ESI, yet a LC grade solvent may not be suitable for MS.
Silica gel particles are commonly used as a stationary phase in high-performance liquid chromatography (HPLC) for several reasons, [13] [14] including: High surface area: Silica gel particles have a high surface area, allowing direct interactions with solutes or after bonding of variety of ligands for versatile interactions with the sample molecules, leading to better separations.