  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  3. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Actuator lever – used to manually trip and reset the circuit breaker. Also indicates the status of the circuit breaker (On or Off/tripped). Most breakers are designed so they can still trip even if the lever is held or locked in the "on" position. This is sometimes referred to as "free trip" or "positive trip" operation.

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An asymmetric or unbalanced fault does not affect each of the phases equally. Common types of asymmetric fault, and their causes: line-to-line fault - a short circuit between lines, caused by ionization of air, or when lines come into physical contact, for example due to a broken insulator. In transmission line faults, roughly 5% - 10% are ...

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    At two multiples of the rated current, the recloser's rapid trip curve can cause a trip (off circuit) in as little as 1.5 cycles (or 30 milliseconds). During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current.

  6. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    However, this also limits the ability of the circuit to satisfy rapidly changing demand, so the addition or removal of large loads causes unstable power. [ citation needed ] A fault current limiter is a nonlinear element which has a low impedance at normal current levels, but presents a higher impedance at fault current levels.

  7. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    Selectivity, also known as circuit breaker discrimination, is the coordination of overcurrent protection devices so that a fault in the installation is cleared by the protection device located immediately upstream of the fault. The purpose of selectivity is to minimize the impact of a failure on the network.

  8. Protective relay - Wikipedia

    en.wikipedia.org/wiki/Protective_relay

    In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...

  9. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    The circuit breaker closest to the downstream fault will send a restraining signal to prevent upstream breakers from tripping instantaneously. The presence of the fault will nevertheless activate the preset trip delay timer(s) of the upstream circuit breaker(s); this will allow an upstream circuit breaker to interrupt the fault, if still ...