enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  3. Certified reference materials - Wikipedia

    en.wikipedia.org/wiki/Certified_reference_materials

    Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration. These reference materials are produced under stringent manufacturing procedures and differ from laboratory reagents in their certification and the traceability of the data provided.

  4. Ultrasonic thickness measurement - Wikipedia

    en.wikipedia.org/wiki/Ultrasonic_Thickness...

    The ultrasonic thickness gauge then calculates the data based on the speed of the sound through the tested sample. The first ultrasonic thickness gauge was made in 1967 by Werner Sobek; [citation needed] a Polish engineer from Katowice. This first ultrasonic thickness gauge measured the velocity of the waves it emitted in particular test ...

  5. ISO/IEC 17025 - Wikipedia

    en.wikipedia.org/wiki/ISO/IEC_17025

    ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories is the main standard used by testing and calibration laboratories. In most countries, ISO/IEC 17025 is the standard for which most labs must hold accreditation in order to be deemed technically competent.

  6. Measurement system analysis - Wikipedia

    en.wikipedia.org/wiki/Measurement_system_analysis

    Common tools and techniques of measurement system analysis include: calibration studies, fixed effect ANOVA, components of variance, attribute gage study, gage R&R, [1] ANOVA gage R&R, and destructive testing analysis. The tool selected is usually determined by characteristics of the measurement system itself.

  7. Precision measurement equipment laboratory - Wikipedia

    en.wikipedia.org/wiki/Precision_Measurement...

    The technicians who work in the PMEL will often specialize in one of these sections. The K-Sections are derived from the primary function of the TMDE. This is based upon the calibration authority. Most labs have three calibration sections divided into K1/K8, K5/K6 and K3/K4 that specialize in like test equipment.

  8. Standard (metrology) - Wikipedia

    en.wikipedia.org/wiki/Standard_(metrology)

    A set of gauge blocks are used as a working standard to check the calibration of measurement tools such as micrometers.. An example of a primary standard was the international prototype of the kilogram (IPK) which was the master kilogram and the primary mass standard for the International System of Units (SI).

  9. Gauge block - Wikipedia

    en.wikipedia.org/wiki/Gauge_block

    Metric gauge block set, 112 pcs Another set with 8 pcs, 125 mm - 500 mm Trolley model. Gauge blocks (also known as gage blocks, Johansson gauges, slip gauges, or Jo blocks) are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific thickness. Gauge ...