  1. Results from the WOW.Com Content Network
  2. Analytical balance - Wikipedia

    en.wikipedia.org/wiki/Analytical_balance

    An analytical balance (or chemical balance) is a class of balance designed to measure small mass in the sub-milligram range. The measuring pan of an analytical balance (0.1 mg resolution or better) is inside a transparent enclosure with doors so that dust does not collect and so any air currents in the room do not affect the balance's operation ...

  3. List of measuring instruments - Wikipedia

    en.wikipedia.org/wiki/List_of_measuring_instruments

    Balance; Check weigher measures precise weight of items in a conveyor line, rejecting underweight or overweight objects. Inertial balance; Katharometer; Mass spectrometers measure the mass-to-charge ratio, not the mass, of ionised particles. Weighing scale; For the ranges of mass-values see: Orders of magnitude (mass)

  4. Weighing scale - Wikipedia

    en.wikipedia.org/wiki/Weighing_scale

    The balance (also balance scale, beam balance and laboratory balance) was the first mass measuring instrument invented. [1] In its traditional form, it consists of a pivoted horizontal lever with arms of equal length – the beam or tron – and a weighing pan [10] suspended from each arm (hence the plural name "scales " for a weighing instrument).

  5. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    However, evaluation of daily performance must be documented to ensure continual production of valid data. A check should first be done to ensure that the data should be seen is precise and accurate. Next, systematic daily checks such as analysing blanks, calibration standards, quality control check samples, and references must be performed to ...

  6. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  7. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    Calibration is conducted incrementally starting working in ascending or descending order. For example, in the case of a 60 tonne load cell, then specific test weights that measure in 5, 10, 20, 40 and 60 tonne increments may be used; a five step calibration process is usually sufficient for ensuring a device is accurately calibrated.

  8. Kibble balance - Wikipedia

    en.wikipedia.org/wiki/Kibble_balance

    The main weakness of the ampere balance method is that the result depends on the accuracy with which the dimensions of the coils are measured. The Kibble balance uses an extra calibration step to cancel the effect of the geometry of the coils, removing the main source of uncertainty.

  9. Metrology - Wikipedia

    en.wikipedia.org/wiki/Metrology

    The NIST-4 Kibble balance, which is used to measure weight via electric current and voltage. With this instrument, the measurement of mass is no longer dependent on a defined mass standard and is instead dependent on natural physical constants. Metrology is the scientific study of measurement. [1]