enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    A fire barrier wall, or a fire partition, is a fire-rated wall assembly that are not structurally self-sufficient. [ 2 ] Fire barrier walls are typically continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, having a fire resistance ...

  3. High-voltage transformer fire barriers - Wikipedia

    en.wikipedia.org/wiki/High-voltage_transformer...

    The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.

  4. California Building Standards Code - Wikipedia

    en.wikipedia.org/wiki/California_Building...

    The California Building Standards Code is the building code for California, and Title 24 of the California Code of Regulations (CCR). It is maintained by the California Building Standards Commission which is granted the authority to oversee processes related to the California building codes by California Building Standards Law. [ 1 ]

  5. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.

  6. California bill would abolish state fire hazard rankings ...

    www.aol.com/news/california-bill-abolish-state...

    A legislative proposal to overhaul California's decades-old wildfire mapping system is generating intense debate, with critics saying it threatens to fundamentally reshape the state's fire and ...

  7. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire doors are sometimes rendered unable to provide their listed fire resistance by ignorance of the intended use and associated restrictions and requirements, or by improper use. For example, fire doors are sometimes blocked open, or carpets are run through them, which would allow the fire to travel past the fire barrier in which the door is ...

  8. Hesco bastion - Wikipedia

    en.wikipedia.org/wiki/Hesco_bastion

    The placement of the barrier is generally very similar to the placement of a sandbag barrier or earth berm except that room must generally be allowed for the equipment used to fill the barrier. [10] The HESCO barriers are varied in sizes and models. Most of the barriers can also be stacked, and they are shipped collapsed in compact sets.

  9. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops