Search results

  1. Results from the WOW.Com Content Network
  2. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  3. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    where: [2] Q f = total residual flow during the test (gallons per minute); c = discharge coefficient (unitless). This is usually 1.0 if using a diffuser. If using a wand to measure the stagnation pressure, the coefficient value depends on the shape of the flow hydrant orifice.

  4. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  5. Miner's inch - Wikipedia

    en.wikipedia.org/wiki/Miner's_inch

    The miner's inch is a method of measuring the amount of flow a particular water supply system (such as a flume or sluice) is capable of supplying. The miner ’s inch measures the amount of water that would flow through a slot of a given area at a given pressure (for example, at a head of 6 inches of water , or 1.5 kPa .)

  6. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [ 1 ] such as fire sprinkler systems , [ 2 ] water supply networks , and irrigation systems.

  7. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    K-Factors have also previously been calculated and published using the United States customary units of pound per square inch (psi) and gallon per minute (gpm). Within the United States, US measurements are still often used instead of metric. [3] [4]

  8. Fire hydrant - Wikipedia

    en.wikipedia.org/wiki/Fire_hydrant

    The tops of the fire hydrants indicate available flow in gallons per minute; the color helps make a more accurate choice of what hydrants will be utilized to supply water to the fire scene. [9] Blue: 1,500 US gallons per minute (95 L/s) or more; very good flow; Green: 1,000–1,499 US gallons per minute (63–95 L/s); good for residential areas

  9. San Francisco Fire Department Auxiliary Water Supply System

    en.wikipedia.org/wiki/San_Francisco_Fire...

    Two 750-US-gallon-per-minute (2,800 L/min) centrifugal pumps deliver fresh water from the city's domestic water system. For safety, the reservoir is broken up into two tanks, and each tank can be emptied separately so that only half of the reservoir is lost in case of a pipe breakage. [4] [5] The tank is set at 758 feet (231 m). [6]