Search results
Results from the WOW.Com Content Network
Beam and block is a construction method to support flooring, especially for ground floors as well as multi story buildings. [1] It is made of cast concrete , one piece of which is a prestressed concrete beam , which can be an inverted T-shaped beam, or lintel, the other piece being a simple rectangular block. [ 1 ]
A common type of insulated slab is the beam and block system (mentioned above) which is modified by replacing concrete blocks with expanded polystyrene blocks. [11] This not only allows for better insulation but decreases the weight of slab which has a positive effect on load bearing walls and foundations.
The floor systems are mostly built from pre-topped double tees. This system evolved from the earlier use of tee systems where the flanges of the T-beams were connected. The concrete is then poured at the top of the tees during the construction to create the floor surface, hence the process is called field-placed concrete topping.
In Latin America, contractors have started to use a form of lift slab construction where load-bearing concrete walls are raised at the same time as the floor slabs. Both the wall panels and the floor slabs are cast on the ground. The walls are attached to the slabs through hinges formed by plastic ropes. As the floors are raised, the walls ...
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
As the temperature climbs to 100 degrees, the soil around a slab or pier and beam foundations shrinks and begins to move around and settle. This movement compresses the foundation, often creating ...
One common example involves steel beams supporting concrete floor slabs. [1] If the beam is not connected firmly to the slab, then the slab transfers all of its weight to the beam and the slab contributes nothing to the load carrying capability of the beam. However, if the slab is connected positively to the beam with studs, then a portion of ...
Formerly headquartered in Houston, Texas, the company was founded as National Components Inc. in 1984 by Johnie Schulte and reincorporated in Delaware in 1991. [3] [8] In 1994, the company closed an agreement to purchase substantially all the assets and business of Ellis Building Components, Inc. located in Tallapoosa, Ga. [9] In 1998, they completed the acquisition of MetalBuilding Components ...