  1. Results from the WOW.Com Content Network
  2. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  3. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...

  4. Voltage converter - Wikipedia

    en.wikipedia.org/wiki/Voltage_converter

    A transformer would be used for higher power. Transformers do not change the frequency of electricity; in many regions with 100–120 V, electricity is supplied at 60 Hz, and 210–240 V regions tend to use 50 Hz. This may affect operation of devices which depend on mains frequency (some audio turntables and mains-only electric clocks, etc ...

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.

  6. Alternating current - Wikipedia

    en.wikipedia.org/wiki/Alternating_current

    A schematic representation of long distance electric power transmission. From left to right: G=generator, U=step-up transformer, V=voltage at beginning of transmission line, Pt=power entering transmission line, I=current in wires, R=total resistance in wires, Pw=power lost in transmission line, Pe=power reaching the end of the transmission line, D=step-down transformer, C=consumers.

  7. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    Frequency and voltage supplied to most premises by country. Mains electricity by country includes a list of countries and territories, with the plugs, voltages and frequencies they commonly use for providing electrical power to low voltage appliances, equipment, and lighting typically found in homes and offices.