Flaman boiler: an attempt to squeeze the largest possible locomotive boiler into the loading gauge by splitting the boiler into two drums: a fire-tube boiler beneath and a steam drum above. [24] flued boiler: A boiler with only one or two large diameter fire-tubes inside a water drum. These later developed into the fire-tube boiler.
A fire-tube boiler exploded at the Grover Shoe Factory in Brockton, Massachusetts, on March 20, 1905, which resulted in the deaths of 58 people and injured 150. Then on December 6, 1906, a boiler in the factory of the P.J. Harney Shoe Company exploded in Lynn, Massachusetts. As a result, the state of Massachusetts enacted the first legal code ...
Variable Speed Fire Pump Controllers were invented and released with a UL Listing for fire pump service in 2003 by Master Control Systems, Inc. [1] [2] Paragraph 10.5.5 in the 2003 edition of NFPA-20 recognized Variable Speed as an accepted method for operating the fire pump. Then in the NFPA-20 2007 edition, section 10.10 was added to clarify ...
A fire-tube boiler is a type of boiler invented in 1828 by Mark Seguin, [1] in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction , heating the water and ultimately creating steam .
Boilers generally have 2 or 3 pressuretrols: a manual-reset pressuretrol, which functions as a safety by setting the upper limit of steam pressure, the operating pressuretrol, which controls when the boiler fires to maintain pressure, and for boilers equipped with a modulating burner, a modulating pressuretrol which controls the amount of fire.
The package boiler is usually a two or three-pass fire-tube boiler with an internal furnace tube. This is similar to the much earlier Scotch boiler . Generating tubes filled with water are in direct contact with the heat source inside the boiler, causing damage to the pipes as well as scaling.
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
A mechanical stoker is a device which feeds coal into the firebox of a boiler. It is standard equipment on large stationary boilers and was also fitted to large steam locomotives to ease the burden of the fireman. The locomotive type has a screw conveyor (driven by an auxiliary steam engine) which feeds the coal into the firebox. The coal is ...