Gas water heaters are generally less energy-efficient than electric water heaters, but the cost of electricity may make gas a better choice. It really just depends on how you use your heating system.
Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...
A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic heating or cooling system. In the interest of improving efficiency and occupant comfort, such systems are commonly divided up into multiple zones. [ 1 ]
A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.
There are three main categories for water temperature controlling devices: Heat Source, Group Control, and Point-of-Use. Heat Source. These are used with central heating systems that use water as a medium. Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications
A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...
Traditional control valves make it inevitable. As we size a control valve, the K v calculated almost certainly will not match the K v of the nearest appropriate valve. For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more ...
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...