Search results
Results from the WOW.Com Content Network
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.
A navigational box that can be placed at the bottom of articles. Template parameters [Edit template data] Parameter Description Type Status State state The initial visibility of the navbox Suggested values collapsed expanded autocollapse String suggested Template transclusions Transclusion maintenance Check completeness of transclusions The above documentation is transcluded from Template ...
Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]
Graphs by hour of California's total electric load, the total load less solar and wind power (known as the duck curve) and solar power output. Data is for October 22, 2016, a day when the wind power output was low and steady throughout the day. In electrical engineering, a load profile is a graph of the variation in the electrical load versus ...
A current transformer presents a negligible load to the primary circuit. [1] Current transformers are the current-sensing units of the power system and are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.
A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram
A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.