enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The neutral current can be determined by adding the three phase currents together as complex numbers and then converting from rectangular to polar co-ordinates. If the three-phase root mean square (RMS) currents are I L 1 {\displaystyle I_{L1}} , I L 2 {\displaystyle I_{L2}} , and I L 3 {\displaystyle I_{L3}} , the neutral RMS current is:

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  4. Harmonics (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Harmonics_(electrical_power)

    A set of three line (or line-to-line) voltages in a balanced three-phase (three-wire or four-wire) power system cannot contain harmonics whose frequency is an integer multiple of the frequency of the third harmonics (i.e. harmonics of order =), which includes triplen harmonics (i.e. harmonics of order = ()). [3]

  5. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Symmetrical components are most commonly used for analysis of three-phase electrical power systems. The voltage or current of a three-phase system at some point can be indicated by three phasors, called the three components of the voltage or the current. This article discusses voltage; however, the same considerations also apply to current.

  6. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power Quality Analyzers, often referred to as Power Analyzers, make a digital recording of the voltage and current waveform (typically either one phase or three phase) and accurately calculate true power (watts), apparent power (VA) power factor, AC voltage, AC current, DC voltage, DC current, frequency, IEC61000-3-2/3-12 Harmonic measurement ...

  7. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    Although an infinite line is assumed, since all quantities are per unit length, the “per length” parts of all the units cancel, and the characteristic impedance is independent of the length of the transmission line. The voltage and current phasors on the line are related by the characteristic impedance as: = (+) (+) = () where the ...

  8. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  9. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...