This sinus rhythm is important because it ensures that the heart's atria reliably contract before the ventricles, ensuring as optimal stroke volume and cardiac output. [ 4 ] In junctional rhythm, however, the sinoatrial node does not control the heart's rhythm – this can happen in the case of a block in conduction somewhere along the pathway ...
When both the heart and lungs are healthy, pulmonary wedge pressure is equal to left ventricle diastolic pressure and can be used as a surrogate for preload. [3] Pulmonary wedge pressure will overestimate left ventricle pressure in people with mitral valve stenosis , pulmonary hypertension and other heart and lung conditions.
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. In electrocardiography , left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.
Test Sensitivity and specificity Approximate peak Description Troponin test: The most sensitive and specific test for myocardial damage. Because it has increased specificity compared with CK-MB, troponin is composed of 3 proteins- Troponin C, Cardic troponin I, and Cardiac troponin T. Troponin I especially has a high affinity for myocardial injury.
Cardiac physiology or heart function is the study of healthy, unimpaired function of the heart: involving blood flow; myocardium structure; the electrical conduction system of the heart; the cardiac cycle and cardiac output and how these interact and depend on one another.
Pediatric intensive care has been established as a sub-specialty of medicine over the past two decades. It grew out of a need for increasingly complex pediatric care, long-term management of disease, and advancements in medical and surgical sub-specialties, as well as, life-sustaining therapies. [9]
Atrial septal defect (ASD) is a congenital heart defect in which blood flows between the atria (upper chambers) of the heart.Some flow is a normal condition both pre-birth and immediately post-birth via the foramen ovale; however, when this does not naturally close after birth it is referred to as a patent (open) foramen ovale (PFO).
Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the area of pathology that is generally concerned with analysis of bodily fluids.