Search results
Results from the WOW.Com Content Network
A diagram with multiple synchronous machine curves; open-circuit saturation curve is the leftmost one. The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field.
Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating).
A 4-bit synchronous counter using JK flip-flops. In a synchronous counter, the clock inputs of the flip-flops are connected, and the common clock simultaneously triggers all flip-flops. Consequently, all of the flip-flops change state at the same time (in parallel). For example, the circuit shown to the right is an ascending (up-counting) four ...
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
In the diagram the taps are [16,14,13,11]. The rightmost bit of the LFSR is called the output bit, which is always also a tap. To obtain the next state, the tap bits are XOR-ed sequentially; then, all bits are shifted one place to the right, with the rightmost bit being discarded, and that result of XOR-ing the tap bits is fed back into the now ...
synchronous presettable 4-bit up/down decade counter 16 DM74LS168: 74x169 1 synchronous presettable 4-bit up/down binary counter 16 SN74LS169B: 74x170 1 16-bit register file (4x4) open-collector 16 SN74170: 74x171 4 quad D flip-flops, clear 16 SN74LS171: 74x172 1 16-bit multiple port register file (8x2) three-state: 24 SN74172: 74x173 4
Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.
The circle diagram can be drawn for alternators, synchronous motors, transformers, induction motors. The Heyland diagram is an approximate representation of a circle diagram applied to induction motors, which assumes that stator input voltage, rotor resistance and rotor reactance are constant and stator resistance and core loss are zero.