The committee worked with the National Bureau of Standards until 1933, when funding was curtailed. In 1921 the Building Code Committee and in 1925 a report was issued titled "Recommended Practice for Arrangement of Building Codes" which consisted of 19 chapters, including Chapter 15 on plumbing. This report was known informally as the "Hoover ...
This code is also used as the basis for the plumbing codes of some other countries. Another model plumbing code published and utilized widely across the United States is the Uniform Plumbing Code , published by the International Association of Plumbing and Mechanical Officials ( IAPMO ), a multinational operation with offices in 13 nations.
The IPC is the most widely used plumbing code in the United States and is also used as the basis for the plumbing code of several other countries [citation needed].Wide adoptions are important as they help reduce manufacturer and end-user costs by allowing the use of materials across a wide user base, thus allowing economies of scale in the production of materials used in construction.
Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.
To allow a single roof penetration as permitted by local building code, sub-vents may be tied together inside the building and exit via a common vent stack, frequently the "main" vent. Adding a vent connection within a long horizontal run with little slope will aid flow, and when used with a cleanout allows for better serviceability.
The Uniform Mechanical Code (UMC) is a model code developed by the International Association of Plumbing and Mechanical Officials to govern the installation, inspection and maintenance of HVAC (heating, ventilating and air-conditioning) and refrigeration systems. It is designated as an American National Standard.
Ventilation should be considered for its relationship to "venting" for appliances and combustion equipment such as water heaters, furnaces, boilers, and wood stoves. Most importantly, building ventilation design must be careful to avoid the backdraft of combustion products from "naturally vented" appliances into the occupied space.
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...