Search results
Results from the WOW.Com Content Network
Pressure and temperature sensors providing pulses can be used to determine mass flow, with division of the pulses by the K-factor, or multiplication with the inverse of the K-factor providing factored totalization, and rate indication. Furthermore, by dividing the pulse rate by the K-Factor, the volumetric throughput per unit time of the rate ...
The law of water balance states that the inflows to any water system or area is equal to its outflows plus change in storage during a time interval. [ 2 ] [ 3 ] In hydrology , a water balance equation can be used to describe the flow of water in and out of a system.
In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.
The ocean contains a natural buffer system to maintain a pH between 8.1 and 8.3. [11] The oceans buffer system is known as the carbonate buffer system. [ 12 ] The carbonate buffer system is a series of reactions that uses carbonate as a buffer to convert C O 2 {\displaystyle \mathrm {CO_{2}} } into bicarbonate . [ 12 ]
K-factor (centrifugation), relative pelleting efficiency of a given centrifuge rotor; K factor (crude oil refining), a system for classifying crude oil; K-factor (fire protection), formula used to calculate the discharge rate from a fire system nozzle; K-factor (metalurgy), formulae used to calculate the bending capacity of sheet metal
= milligrams of pollutant per cubic meter of air at sea level atmospheric pressure and T: ppmv = air pollutant concentration, in parts per million by volume T = ambient temperature in K = 273. + °C 0.082057338 = Universal gas constant in L atm mol −1 K −1: M = molecular mass (or molecular weight) of the air pollutant
The pH range is commonly given as zero to 14, but a pH value can be less than 0 for very concentrated strong acids or greater than 14 for very concentrated strong bases. [ 2 ] The pH scale is traceable to a set of standard solutions whose pH is established by international agreement. [ 3 ]
[15] k 1 is the rate constant for chemical uptake from water at the respiratory surface (L*kg −1 *d −1). [15] C WD is the chemical concentration dissolved in water (g*L −1). [15] k 2,k E,k G,k B are rate constants that represent excretion from the organism from the respiratory surface, fecal excretion, metabolic transformation, and growth ...