A Lally column is a round or square thin-walled structural steel column filled with concrete, [1] and oriented vertically to provide support to beams or timbers stretching over long spans. Lally columns are an engineered component and as such must be installed exactly as the design engineer specified.
size 2 from 6.5 feet (2.0 m) to 11 feet (3.4 m), size 3 from 8 feet (2.4 m) to 13 feet (4.0 m), size 4 from 10.5 feet (3.2 m) to 16 feet (4.9 m). The safe load for each prop depends upon the size and extension of the prop. Size 1, 2 and 3 props can take about 34 kN unextended, dropping progressively to less than half of that when fully extended.
In the recent past, HSS was commonly available in mild steel, such as A500 grade B. Today, HSS is commonly available in mild steel, A500 grade C. Other steel grades available for HSS are A847 (weathering steel), A1065 (large sections up to 50 inch sq made with SAW process), and recently approved A1085 (higher strength, tighter tolerances than ...
In Australia, these steel sections are commonly referred to as Universal Beams (UB) or Columns (UC). The designation for each is given as the approximate height of the beam, the type (beam or column) and then the unit metre rate (e.g., a 460UB67.1 is an approximately 460 mm (18.1 in) deep universal beam that weighs 67.1 kg/m (135 lb/yd)). [6]
A steel column is extended by welding or bolting splice plates on the flanges and webs or walls of the columns to provide a few inches or feet of load transfer from the upper to the lower column section. A timber column is usually extended by the use of a steel tube or wrapped-around sheet-metal plate bolted onto the two connecting timber sections.
In addition to the descriptive steel grade naming system indicated above, within EN 10027-2 is defined a system for creating unique steel grade numbers. While less descriptive and intuitive than the grand names they are easier to tabulate and use in data processing applications.
Steel studs are gaining popularity as a non-combustible alternative, especially for non load-bearing walls, and are required in some firewalls. In New Zealand, the required lumber size and spacing of wall studs are determined using NZS 3604 Timber-framed buildings table 8.2 for loadbearing walls and table 8.4 for non-loadbearing walls. [4]