enow.com Web Search

  1. Ads

    related to: hvac returns in every room at 2 months and 3 lines of business
  2. supplyhouse.com has been visited by 100K+ users in the past month

    • HVAC Tools

      From Brands Including Fieldpiece,

      Malco, Bacharach, and More.

    • Venting Supplies

      Shop Our Selection of Ducts, Vents,

      and Connectors For Your Systems.

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The respective tables of data were generally developed by using the more complex transfer function method to determine the various cooling loads for different types of heating. [2] [3] The results gained by doing so are then normalized for each type of heat gain used for the tables, CLTD, CLF, and SCL. [4]

  3. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  4. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7] (The return should be efficient enough to draw off the cooler air.) [10] [11]

  5. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    At a certain plane in the room, the airflow rate returned to the upper zone is equal to the supply air. The plane divides the room into occupied zone and upper zone and leads to thermal stratification: the hot and contaminated air is concentrated in the upper zone, and the air in the occupied zone is cool and fresh. [2]

  6. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  7. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    A round diffuser in an HVAC system. Diffusers are very common in heating, ventilating, and air-conditioning systems. [3] Diffusers are used in both all-air and air-water HVAC systems, as part of room air distribution subsystems, and serve several purposes: To deliver both conditioning and ventilating air

  8. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems.

  9. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [ 1 ] [ 2 ] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

  1. Ads

    related to: hvac returns in every room at 2 months and 3 lines of business