Search results
Results from the WOW.Com Content Network
Diagram of a simple microscope. There are two basic types of optical microscopes: simple microscopes and compound microscopes. A simple microscope uses the optical power of a single lens or group of lenses for magnification. A compound microscope uses a system of lenses (one set enlarging the image produced by another) to achieve a much higher ...
Resolving power is the capacity of an instrument to resolve two points which are close together. Specifically, resolving power may refer to: Angular resolution
In a dry objective or condenser, this gives a maximum NA of 0.95. In a high-resolution oil immersion lens, the maximum NA is typically 1.45, when using immersion oil with a refractive index of 1.52. Due to these limitations, the resolution limit of a light microscope using visible light is about 200 nm.
For example, an electron at an energy of 10 keV has a wavelength of 0.01 nm, allowing the electron microscope (SEM or TEM) to achieve high resolution images. Other massive particles such as helium, neon, and gallium ions have been used to produce images at resolutions beyond what can be attained with visible light.
The ability of a lens to resolve detail is usually determined by the quality of the lens, but is ultimately limited by diffraction.Light coming from a point source in the object diffracts through the lens aperture such that it forms a diffraction pattern in the image, which has a central spot and surrounding bright rings, separated by dark nulls; this pattern is known as an Airy pattern, and ...
In light microscopy, oil immersion is a technique used to increase the resolving power of a microscope. This is achieved by immersing both the objective lens and the specimen in a transparent oil of high refractive index, thereby increasing the numerical aperture of the objective lens.
A 4Pi microscope is a laser scanning fluorescence microscope with an improved axial resolution. With it the typical range of the axial resolution of 500–700 nm can be improved to 100–150 nm, which corresponds to an almost spherical focal spot with 5–7 times less volume than that of standard confocal microscopy .
He investigated the need for a brighter electron source in the microscope, positing that cold field emission guns would be feasible. [9] Through this and other iterations, Crewe was able to improve the resolution of the STEM from 30 Ångstroms (Å) down to 2.5 Å. [10] Crewe's work made it possible to visualize individual atoms for the first ...