ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.
The CBE Thermal Comfort Tool for ASHRAE 55 [9] allows users to input the six comfort parameters to determine whether a certain combination complies with ASHRAE 55. The results are displayed on a psychrometric or a temperature-relative humidity chart and indicate the ranges of temperature and relative humidity that will be comfortable with the ...
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
The study indicates that stratified buildings tend to overheat or overcool based on the temperature at the thermostat, which tends to be lower than the overall heat energy present in the room. The study also showed that energy waste due to stratification was present at ceiling heights ranging from 20 ft. to 40 ft, and higher ceilings caused ...
Hypothermia is another serious concern and occurs when your body temperature drops below 96 degrees. Perhaps surprisingly, hypothermia can occur in temperatures as warm as 60 degrees.
The norm ISO 7730 and the ASHRAE 55 standard give the predicted percentage of dissatisfied occupants (PPD) as a function of the radiant temperature asymmetry and specify the acceptable limits. In general, people are more sensitive to asymmetric radiation caused by a warm ceiling than that caused by hot and cold vertical surfaces.
ASHRAE's Standard 55-2017 has minimum standards of 8.3 L/s/person. In one study, raising the rate to 15 L/s/person increased performance by 1.1% and decreased sick building symptoms by 18.8%. [ 12 ] Whole Building Design Guide recommends separating ventilation from thermal conditioning so as to increase comfort.