enow.com Web Search

  1. Ad

    related to: best way to insulate attic ducts in garage ceiling pictures and plans

Search results

  1. Results from the WOW.Com Content Network
  2. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    Vertical section through a commercial building using HVAC plenum instead of airspace plenum. When both the supply and return ducts are constructed in this manner, it is possible to insulate the ducts and the dropped ceiling so that the upper airspace is not heated or cooled, increasing energy efficiency. This is a fully enclosed plenum.

  3. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    Air returns from the room at ceiling level or the maximum allowable height above the occupied zone. [1] The UFAD system takes advantage of the thermal plume and stratification phenomenon: the conditioned air is supplied directly to the occupied zone (OZ). The thermal plumes generated by the occupants and other heat sources introduce the ...

  4. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts commonly also deliver ventilation air as part of the supply air. As such, air ducts are one method of ensuring acceptable indoor air quality as well as thermal comfort. A duct system is also called ductwork. Planning (laying out), sizing, optimizing, detailing, and finding the pressure losses through a duct system is called duct design. [2]

  5. Cellulose insulation - Wikipedia

    en.wikipedia.org/wiki/Cellulose_insulation

    Insulation reduces sound travelling through walls and between floor levels. Cellulose provides mass and damping. This reduces noise in two ways: it reduces the lateral vibration of sheetrock and attenuates the passage of sound along cavities. Cellulose is approximately three times denser than fiberglass, providing a slight improvement in sound ...

  6. Domestic roof construction - Wikipedia

    en.wikipedia.org/wiki/Domestic_roof_construction

    Warm air rises, so ceiling insulation is designed to have a higher r-value and the insulation is often installed between the ceiling joists or rafters. A properly insulated and ventilated roof is called a cold roof. A warm roof is a roof that is not ventilated, [9] where the insulation is placed in line with the roof pitch. [10]

  7. Radiant barrier - Wikipedia

    en.wikipedia.org/wiki/Radiant_barrier

    The final method of installing a radiant barrier in an attic is to lay it over the top of the insulation on the attic floor. While this method can be more effective in the winter [ 12 ] there are a few potential concerns with this application, which the US Department of Energy [ 11 ] and the Reflective Insulation Manufacturers Association ...

  8. Get breaking Finance news and the latest business articles from AOL. From stock market news to jobs and real estate, it can all be found here.

  9. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    This presents a situation where floors underneath the neutral axis of the building have a net negative pressure, whereas floors above the neutral axis have a net positive pressure. The net negative pressure on lower floors can induce outdoor air to infiltrate the building through doors, windows, or ductwork without backdraft dampers.

  1. Ad

    related to: best way to insulate attic ducts in garage ceiling pictures and plans