Current limiting reactor. The main motive of using current limiting reactors is to reduce short-circuit currents so that circuit breakers with lower short circuit breaking capacity can be used. They can also be used to protect other system components from high current levels and to limit the inrush current when starting a large motor. [5]
Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is also used to define a type of overcurrent protective device.
It consists of a power capacitor connected in series with a bidirectional thyristor valve and, usually, a current limiting reactor . The thyristor switched capacitor is an important component of a Static VAR Compensator (SVC), [ 1 ] [ 2 ] where it is often used in conjunction with a thyristor controlled reactor (TCR).
According to the patent application [5] the reactor design has some notable characteristics, that sets it apart from other reactor designs. It uses uranium hydride (UH 3) "low-enriched" to 5% uranium-235—the remainder is uranium-238—as the nuclear fuel, rather than the usual metallic uranium or uranium dioxide that composes the fuel rods of contemporary light-water reactors.
Series reactors are used as current limiting reactors to increase the impedance of a system. They are also used for neutral earthing. Such reactors are also used to limit the starting currents of synchronous electric motors and to compensate reactive power in order to improve the transmission capacity of power lines. [3]
English: Schematic diagram of an Advanced Gas-cooled Reactor type nuclear reactor 1. Charge tubes 2. Control rods 3. Graphite moderator 4. Fuel assemblies 5. Concrete pressure vessel and radiation shielding 6. Gas circulator 7. Water 8. Water circulator 9. Heat exchanger 10. Steam
About 1/3 are boiling water reactors where the primary coolant undergoes phase transition to steam inside the reactor. About 2/3 are pressurized water reactors at even higher pressure. Current reactors stay under the critical point at around 374 °C and 218 bar where the distinction between liquid and gas disappears, which limits thermal ...
The current in the TCR is varied from maximum (determined by the connection voltage and the inductance of the reactor) to almost zero by varying the "Firing Delay Angle", α. α is defined as the delay angle from the point at which the voltage becomes positive to the point at which the thyristor valve is turned on and current starts to flow.