The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:
HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. " Refrigeration " is sometimes added to the field's abbreviation as HVAC&R or HVACR , or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers ).
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
This method, also known as the adaptive comfort model, is applicable in buildings without mechanical cooling (and no operating heating system) where occupants' met rates are 1.0-1.3 met and their clothing levels are 0.5-1.0 clo. For this model the standard provides a graph of acceptable indoor temperature limits at prevailing mean outdoor ...
As the original technical software partner of ACCA, [3] Wrightsoft Corp became the first HVAC software company to create a computerized version of their Manual J, Manual D, and Manual N calculation methods. The Air Conditioning Contractors of America and Wrightsoft released the very first Manual J Load calculation software (Right-J) in February ...
Part 3 of the Fan Application Manual, helps to identify and correct problems with the performance and operation of the air moving system after fan installation. AMCA Publication 203 - Field Performance Measurement of Fan Systems. Part 4 of the Fan Application Manual, reviews the methods of making field measurements for calculating the actual ...