The socket is rectangular, with lateral key pins and indentations to maintain polarisation, and to prevent insertion of a plug with different current ratings. Three single-phase general purpose connectors were rated 10 A, 16 A and 20 A; and a three-phase industrial connector rated 10 A; all of them have different key-pin positioning so plugs ...
The numerals preceding the hyphen encode the number of poles (current-carrying terminals) and wires connected to it, the voltage, and single- or three-phase power. [citation needed] A connector with ground terminal has more wires than poles: two-pole, three-wire; or four-pole, five-wire; etc.
BS 546, Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50–60 Hz) circuits up to 250 V is an older British Standard for three-pin AC power plugs and sockets: four sizes with current capacities from 2 A to 30 A. Originally published in April 1934, it was updated by a 1950 edition which is still current, [1 ...
This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.
Semko 17 were 3/4-pin 3-phase connectors, with (4-pin) or without (3-pin) a neutral connector. Earth were provided via the shield. The connectors were available in different sizes, 16 A with rounded corners; 25 A and 63 A were rectangular. These connectors were used mainly in industrial and agricultural installations.
At low voltage electricity may be supplied by the distributor (DNO) as either single or three phase. A single phase supply will comprise a single line conductor and a neutral conductor. A three phase supply will comprise three line conductors each pair with a phase separation of 120 degrees and (optionally) a neutral conductor.
In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.
With single-phase sockets (T11, T13, T21, T23) the protective collar is 13 mm (+5 mm) deep, with three-phase sockets (T15, T25) 17.5 mm (+1 mm) deep. Dimensions of the connector Plugs according to T11 and T21 are between 13 mm and 14.5 mm wide, those according to T13 and T23 between 14.5 mm and 20 mm wide.