enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Lifting equipment - Wikipedia

    en.wikipedia.org/wiki/Lifting_equipment

    Lifting equipment can be assigned a Working Load Limit (WLL) in the interests of avoiding failure; Working Load Limit is calculated by dividing the Minimum Breaking Load of the equipment by a safety factor. [5] WLL as a concept is not restricted to lifting, being also relevant for mooring ropes. [6]

  3. Turndown ratio - Wikipedia

    en.wikipedia.org/wiki/Turndown_ratio

    Turndown ratio refers to the width of the operational range of a device, and is defined as the ratio of the maximum capacity to minimum capacity. For example, a device with a maximum output of 10 units and a minimum output of 2 units has a turndown ratio of 5.

  4. Working load limit - Wikipedia

    en.wikipedia.org/wiki/Minimum_breaking_strength

    This load represents a force that is much less than that required to make the lifting equipment fail or yield. The WLL is calculated by dividing MBL by a safety factor (SF). An example of this would be a chain that has a MBL of 2000 lbf (8.89 kN ) would have a SWL or WLL of 400 lbf (1.78 kN) if a safety factor of 5 (5:1, 5 to 1, or 1/5) is used.

  5. Factor of safety - Wikipedia

    en.wikipedia.org/wiki/Factor_of_safety

    If there is a part with a required design factor of 3 and a margin of 1, the part would have a safety factor of 6 (capable of supporting two loads equal to its design factor of 3, supporting six times the design load before failure). A margin of 0 would mean the part would pass with a safety factor of 3.

  6. Compression ratio - Wikipedia

    en.wikipedia.org/wiki/Compression_ratio

    For example, if the static compression ratio is 10:1, and the dynamic compression ratio is 7.5:1, a useful value for cylinder pressure would be 7.5 1.3 × atmospheric pressure, or 13.7 bar (relative to atmospheric pressure). The two corrections for dynamic compression ratio affect cylinder pressure in opposite directions, but not in equal strength.

  7. List of abbreviations in oil and gas exploration and production

    en.wikipedia.org/wiki/List_of_abbreviations_in...

    TGOR – total gas oil ratio (GOR uncorrected for gas lift gas present in the production fluid [citation needed]) TH – tubing hanger; THCP – tubing hanger crown plug; Thr/Th# – thruster ('#'- means identification letter/number of the equipment, e.g. thr3 or thr#3 means "thruster no. 3" [citation needed]) THD – tubing head; THERM ...

  8. Maximum allowable operating pressure - Wikipedia

    en.wikipedia.org/wiki/Maximum_allowable...

    Maximum Allowable Operating Pressure (MAOP) is a pressure limit set, usually by a government body, which applies to compressed gas pressure vessels, pipelines, and storage tanks. For pipelines, this value is derived from Barlow's Formula , which takes into account wall thickness, diameter, allowable stress (which is a function of the material ...

  9. Compressor characteristic - Wikipedia

    en.wikipedia.org/wiki/Compressor_characteristic

    Compressor characteristic is a mathematical curve that shows the behaviour of a fluid going through a dynamic compressor.It shows changes in fluid pressure, temperature, entropy, flow rate etc.) with the compressor operating at different speeds.