Search results
Results from the WOW.Com Content Network
The laryngeal tube was developed in Germany and introduced to the European market by VBM Medizintechnik in the autumn of 1999. [18] Since then the design has been modified several times. Currently four different models are used: the standard tube as single use or re-use models and the modified tube (laryngeal tube-Suction II) as single use or ...
The operator introduces the video laryngoscope through the mouth with a technique similar to direct laryngoscopy. The larynx and vocal cords are visualized via the camera and the operator is able to pass the endotracheal tube through the vocal cords and into the trachea under direct visualization on the video monitor. [ 9 ]
Compared to a cuffed tracheal tube, extraglottic devices provide less protection against aspiration but are more easily inserted and causes less laryngeal trauma. [27] Limitations of extraglottic devices arise in morbidly obese patients, lengthy surgical procedures, surgery involving the airways, laparoscopic procedures and others due to its ...
laryngeal mask airway, laryngeal tube [ edit on Wikidata ] The Combitube —also known as the esophageal tracheal airway or esophageal tracheal double-lumen airway —is a blind insertion airway device (BIAD) used in the pre-hospital and emergency setting. [ 1 ]
A laryngeal mask is composed of an airway tube that connects to an elliptical mask with a cuff which is inserted through the patient's mouth, down the windpipe, and once deployed forms an airtight seal on top the glottis (unlike tracheal tubes which pass through the glottis) allowing a secure airway to be managed by a health care provider.
As the Eschmann tracheal tube introducer is considerably less rigid than a conventional stylet, this technique is considered to be a relatively atraumatic means of tracheal intubation. [ 20 ] [ 21 ] The tracheal tube exchanger is a hollow catheter , 56 to 81 cm (22.0 to 31.9 in) in length, that can be used for removal and replacement of ...
A tracheostomy tube or endotracheal tube with a 6 or 7 mm internal diameter is then inserted, the cuff is inflated, and the tube is secured. The person performing the procedure might utilize a bougie device, a semi-rigid, straight piece of plastic with a 25-mm tip at a 30-degree angle, to provide rigidity to the tube and assist with guiding its ...
In anaesthesia and advanced airway management, rapid sequence induction (RSI) – also referred to as rapid sequence intubation or as rapid sequence induction and intubation (RSII) or as crash induction [1] – is a special process for endotracheal intubation that is used where the patient is at a high risk of pulmonary aspiration.