A boiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler. The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler.
The ASME Boiler & Pressure Vessel Code (BPVC) is an American Society of Mechanical Engineers (ASME) standard that regulates the design and construction of boilers and pressure vessels. [1] The document is written and maintained by volunteers chosen for their technical expertise . [ 2 ]
Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.
Feed check valve - regulates the flow of water into the boiler and prevents the back flow of water in case of failure of the feed pump. Steam stop valve - regulates the flow of steam that is produced in the boiler to the steam pipe, and may also be used to stop the supply of steam from the boiler
The design of any superheated steam plant presents several engineering challenges due to the high working temperatures and pressures. One consideration is the introduction of feedwater to the boiler. The pump used to charge the boiler must be able to overcome the boiler's operating pressure, else water will not flow. As a superheated boiler is ...
A common application of the multistage centrifugal pump is the boiler feedwater pump. For example, a 350 MW unit would require two feedpumps in parallel. Each feedpump is a multistage centrifugal pump producing 150 L/s at 21 MPa. All energy transferred to the fluid is derived from the mechanical energy driving the impeller.
The Pressure Equipment Directive (PED) 2014/68/EU (formerly 97/23/EC) [1] of the EU sets out the standards for the design and fabrication of pressure equipment ("pressure equipment" means steam boilers, pressure vessels, piping, safety valves and other components and assemblies subject to pressure loading) generally over one liter in volume and having a maximum pressure more than 0.5 bar gauge.
This kind of heater will normally require a feed pump at both the feed inlet and outlet since the pressure in the heater is between the boiler pressure and the condenser pressure. A deaerator is a special case of the open feedwater heater which is specifically designed to remove non-condensable gases from the feedwater.