Search results
Results from the WOW.Com Content Network
However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...
The active devices are by nature self-adjusting. [10] The tap-changing transformers with under-load tap-changing (ULTC) feature can be used to control the voltage directly. The operation of all tap-changing transformers in the system needs to be synchronized between the transformers [15] and with the application of shunt capacitors. [16]
Using a PMU, it is simple to detect abnormal waveform shapes. A waveform shape described mathematically is called a phasor.. A phasor measurement unit (PMU) is a device used to estimate the magnitude and phase angle of an electrical phasor quantity (such as voltage or current) in the electricity grid using a common time source for synchronization.
Both linear spacing and power-of-two-style Vernier spacing can be employed in establishing the tap positions, e.g., a four-tap transformer can provide taps at 0.25, 0.5, 0.75, 1.0 (linear) or 0.0625, 0.125, 0.25, and 0.5 (Vernier). (The limitations of the Vernier—in this case, that the maximum obtainable amplitude is 0.9375—are less ...
Transformers designed for below-grade installation can be designed for periodic submersion in water. [14] Distribution transformers may include an off-load tap changer, which slightly adjusts the ratio between primary and secondary voltage to bring the customer's voltage within the desired range on long or heavily loaded lines. [citation needed]
Real transformer equivalent circuit. One case of voltage regulation is in a transformer. The unideal components of the transformer cause a change in voltage when current flows. Under no load, when no current flows through the secondary coils, V nl is given by the ideal model, where V S = V P *N S /N P.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Phase-Shifting Transformers (PST) are generally used for these applications and can just be a Phase-Angle Regulator (PAR) or control both phase-angle and voltage. The most straightforward phase angle compensation device would be to replace the tap changer on PAR with thyristors to switch portions of the winding in and out, forming a Thyristor ...