Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
When engaged, a compound automatic wire stripper first simultaneously grips the wire in one side and in the other side closes its shaped blades cutting the insulation around the conductor. After the sides have completed their strokes the two sides of the mechanism spread apart to push the cut tube of insulation from the end of the conductor.
The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors. For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level.
Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air temperature of 30 °C. In the United States , 105 °C is allowed with ambient of 40 °C, for larger power cables, especially those operating at more than 2 kV.
They are also referred to as "pin & sleeve" connectors in North America [1] or as "CeeForm" connectors in the entertainment industry. [2] The maximum voltage allowed by the standard is 1000 V DC or AC; the maximum current, 800 A; and the maximum frequency, 500 Hz. The ambient temperature range is −25 °C to 40 °C. [3]
Sometimes 4 mm 2 cable is used if very long cable runs (to help reduce voltage drop) or derating factors such as very thick thermal insulation are involved. 1.5 mm 2 mineral-insulated copper-clad cable (known as pyro) may also be used (as mineral insulated cable can withstand heat more effectively than normal PVC) though more care must be taken ...
White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits Black: 6 or 8 AWG wire (13.3 mm 2 or 8.37 mm 2) for 60- and 45-amp circuits, respectively Grey: usage for underground installations, designated as "underground feeder" (UF) cables [4]
Twist-on wire connectors are not generally recommended for use with aluminum wire in the United States. [1] The U.S. Consumer Product Safety Commission disapproves wire nuts for aluminum wire; instead, special crimp connectors are called for, and as of 2011 the CPSC asserted qualified, second-preference approval of a certain kind of screw ...