Results from the WOW.Com Content Network
Originally a trade name as Cam-Lok, it is now a generic term. [2] Each camlock connector carries a single phase, pole, or conductor; multiple camlock connectors will be used to make a complete electrical supply or circuit. The most common form is the 16 series, rated at 400 amperes with 105 °C terminations.
Where more current carrying capacity is required, such as between generator sets and distribution boards, VEAM Powerlocks or Cam-Loks may be used. These connectors are single pole so five are required to accommodate all three phases, neutral and ground. Powerlocks have a rating of 400 A or 660 A at 1 kV.
Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.
For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate. For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines rated current as the maximum current that a breaker is designed to carry continuously.
Nevertheless, the potential exists for connection errors, such as failing to properly connect earth or neutral, attempting connection / disconnection under load, incomplete connection of parallel circuits, or inappropriate combinations of circuit breakers and downstream equipment. For this reason all single-pole connectors including Powerlock ...
A generator interlock kit (or a transfer switch), eliminates the need for extension cords to power appliances. [2]Like a transfer switch, an interlock kit lets the generator energize the panel and all of its circuits (up to the load capacity of the generator); not just corded appliances.
Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.
A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.