Ads
related to: 6 in barometric damper for furnacezoro.com has been visited by 1M+ users in the past month
Search results
Results from the WOW.Com Content Network
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...
A register's damper provides a critical function. Primarily, the damper allows the amount of hot or cool air entering a room to be controlled, providing for more accurate control over room temperature. [7] Dampers also allow air to be shut off in unused rooms, improving the efficiency of the HVAC system.
Such a system contains a boiler, furnace, or heat pump to heat water, steam, or air in a central location such as a furnace room in a home, or a mechanical room in a large building. The heat can be transferred by convection, conduction, or radiation. Space heaters are used to heat single rooms and only consist of a single unit.
The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other purposefully designed openings or containers, resulting from air buoyancy.
The stack damper contained within works like a butterfly valve and regulates draft (pressure difference between air intake and air exit) in the furnace, which is what pulls the flue gas through the convection section. The stack damper also regulates the heat lost through the stack.
Most systems will use motorized dampers to control the air mixing, and controlled by the building management system (BMS), or controls system. Typically as the fresh air and exhaust air dampers are driven from 0% open to 100% open, the mixing damper will in turn be driven from 100% open to 0% open, so as to always ensure a constant volume of ...
smoke damper A damper or adjustable louver designed to augment the ventilation of a space during a fire. split system A split system is the combination of an outdoor unit and an indoor unit. This is the most common type of system. superheat The number of degrees a vapor is above its boiling point at a specific pressure. subcooling
After the control of air flow and temperature was standardized, the use of electromechanical relays in ladder logic to switch dampers became standardized. Eventually, the relays became electronic switches, as transistors eventually could handle greater current loads. By 1985, pneumatic controls could no longer compete with this new technology ...
Ads
related to: 6 in barometric damper for furnacezoro.com has been visited by 1M+ users in the past month