  2. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V or 120v. Countries such as Mexico may adopt the NFPA standard as their national electrical code, with local amendments similar to those in United States jurisdictions.

  3. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    The voltages between the three phases are the same in magnitude, however the voltage magnitudes between a particular phase and the neutral vary. The phase-to-neutral voltage of two of the phases will be half of the phase-to-phase voltage. The remaining phase-to-neutral voltage will be √ 3 /2 the phase-to-phase voltage. So if A–B, B–C and ...

  4. IEC 60038 - Wikipedia

    en.wikipedia.org/wiki/IEC_60038

    Where two voltages are given below separated by "/", the first is the root-mean-square voltage between a phase and the neutral connector, whereas the second is the corresponding root-mean-square voltage between two phases (exception: the category shown below called "One Phase", where 240 V is the root-mean-square voltage between the two legs of a split phase).

  5. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    277/480 V 347/600 V 60 Hz NEMA 5-20R outlets, which are similar to type B but have a T-shaped neutral slot, are sometimes used for higher current 120 V equipment (up to 20 A). Homes are typically provided with 120/240 V split-phase power; NEMA 14-30R and 14-50R receptacles are provided on 240 V circuits for clothes dryers and electric stoves.

  6. North American Charging System - Wikipedia

    en.wikipedia.org/wiki/North_American_Charging_System

    When AC power is used, the NACS system can deliver up to 80 amperes at 277 volts (a voltage derived from a three-phase commercial power supply at 480 volts). [ 2 ] [ 26 ] However, in a common configuration, NACS provides up to 48 amperes of current at 240 volts (the typical residential voltage of the North American split-phase electric power ...

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The neutral conductor is connected to ground at the transformer center tap. Circuits for lighting and small appliance power outlets use 120 V circuits connected between one line and neutral. High-demand applications, such as ovens, are often powered using 240 V AC circuits—these are connected between the two 120 V AC lines.

  8. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  9. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    In electrical engineering, ground and neutral (earth and neutral) are circuit conductors used in alternating current (AC) electrical systems. The neutral conductor receives and returns alternating current to the supply during normal operation of the circuit; to limit the effects of leakage current from higher-voltage systems, the neutral ...