NEC Division System gas & dust groups Area Group Representative materials Class I, Divisions 1 & 2 A Acetylene B Hydrogen C Ethylene D Propane, methane Class II, Divisions 1 & 2 E (Division 1 only) Metal dusts, such as magnesium (Division 1 only) F Carbonaceous dusts, such as carbon & charcoal G
Certified and labelled for use in areas with specific hazardous conditions: for indoor and outdoor use in locations classified as Class II, Groups E, F, or G as defined in NFPA standards such as the NEC. 10: MSHA. Meets the requirements of the Mine Safety and Health Administration, 30 CFR Part 18 (1978). 11: General-purpose.
Class 1 goods are subdivided further into one of 6 distinct divisions, that describes the predominant explosive hazard that exists if that article was to detonate or activate while in transport or storage. These divisions are as follows: Class 1: Explosives. Division 1.1: Explosive that has a mass explosion hazard. A mass explosion is a ...
The rules contained in this section can be used as an alternative to the minimum requirements specified in Division 1. Generally the Division 2 rules are more onerous than in Division 1 with respect to materials, design and nondestructive examinations but higher design stress intensity values are allowed. [17]
The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association. [1]
In Europe, a double insulated appliance must be labelled Class II or double insulated or bear the double insulation symbol: ⧈ (a square inside another square). As such, the appliance should not be connected to an earth conductor because the high-impedance casing will cause only low-fault currents that are unable to trigger the fusible cut-out.
An aerosol must be assigned to Division 2.2 if the contents contain 1% by mass or less flammable components and the heat of combustion is less than 20 kJ/g. Division 2.3 : Toxic Gas Gas poisonous by inhalation means a material which is a gas at 20 °C or less and a pressure of 101.3 kPa (a material which has a boiling point of 20 °C or less at ...
The United States National Electrical Code (NEC) specifies minimum acceptable wiring methods and materials for many states and municipalities. [2] It is sponsored by the National Fire Protection Association (NFPA) and has been periodically revised since 1897. Local jurisdictions usually adopt the NEC or another published code and then ...