Search results
Results from the WOW.Com Content Network
The K-factor is the bending capacity of sheet metal, and by extension the forumulae used to calculate this. [1] [2] [3] Mathematically it is an engineering aspect of geometry. [4] Such is its intricacy in precision sheet metal bending [5] (with press brakes in particular) that its proper application in engineering has been termed an art. [4] [5]
The K Factor also helps calculate the peak-to-daily ratio of traffic. K30 helps maintain a healthy volume to capacity ratio. [3] K50 and K100 will sometimes be seen. K50 and K100 will not use the 30th highest hourly traffic volumes but the 50th or 100th highest hourly traffic volume when calculating the K factor.
K correction converts measurements of astronomical objects into their respective rest frames. The correction acts on that object's observed magnitude (or equivalently, its flux ). Because astronomical observations often measure through a single filter or bandpass, observers only measure a fraction of the total spectrum , redshifted into the ...
K-factor (Elo rating system), a constant used in Elo rating system; K-factor (marketing), the growth rate of websites, apps, or a customer base; K-factor (sheet metal), the ratio of location of the neutral line to the material thickness; The K Factor, a fictional TV show within Harry Hill's TV Burp; Bondi k-factor, the "k" in Bondi k-calculus
where K is the stress intensity factor (with units of stress × length 1/2) and is a dimensionless quantity that varies with the load and geometry. Theoretically, as r goes to 0, the stress σ i j {\displaystyle \sigma _{ij}} goes to ∞ {\displaystyle \infty } resulting in a stress singularity. [ 5 ]
If the upper and lower specification limits of the process are USL and LSL, the target process mean is T, the estimated mean of the process is ^ and the estimated variability of the process (expressed as a standard deviation) is ^, then commonly accepted process capability indices include:
, column effective length factor; This formula was derived in 1744 by the Swiss mathematician Leonhard Euler. [2] The column will remain straight for loads less than the critical load. The critical load is the greatest load that will not cause lateral deflection (buckling). For loads greater than the critical load, the column will deflect ...
Pressure and temperature sensors providing pulses can be used to determine mass flow, with division of the pulses by the K-factor, or multiplication with the inverse of the K-factor providing factored totalization, and rate indication. Furthermore, by dividing the pulse rate by the K-Factor, the volumetric throughput per unit time of the rate ...