Search results
Results from the WOW.Com Content Network
A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [12] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating.
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...
In Canada and the United States, the Canadian Electrical Code (CEC) and the National Electrical Code (NEC), respectively, use the circular mil to define wire sizes larger than 0000 AWG. In many NEC publications and uses, large wires may be expressed in thousands of circular mils, which is abbreviated in two different ways: kcmil [ 1 ] or MCM ...
The resistance of copper wire is approximately 1 ohms / 1000 feet for 10 AWG, 10 ohms / 1000 feet for 20 AWG, 100 ohms / 1000 feet for 30 AWG, and so on. [ 5 ] : 27 Because aluminum wire has a conductivity of approximately 61% of copper, an aluminum wire has nearly the same resistance as a copper wire that is two sizes ...
All directors refers to people who sat on the board of at least one Fortune 100 company between 2008 and 2012. The Pay Pals project relies on financial research conducted by the Center for Economic Policy and Research. Sources: Google Finance, Yahoo Finance, CHS SEC filings (2008, 2009, 2010).
Galvanized rigid conduit (GRC) is galvanized steel tubing, with a tubing wall that is thick enough to allow it to be threaded. Its common applications are in commercial and industrial construction. [1] It is designed to protect wire and connectors. Intermediate metal conduit (IMC) is a steel tubing heavier than EMT but lighter than RMC. It may ...
The Baseball Hall of Fame ballot is being mailed to 400 members of the Baseball Writers Association of America this week, and that ballot includes 14 candidates appearing for the very first time.