enow.com Web Search

  1. Ad

    related to: transformer impedance calculation formula for series 1

Search results

  1. Results from the WOW.Com Content Network
  2. Equivalent impedance transforms - Wikipedia

    en.wikipedia.org/wiki/Equivalent_impedance...

    The number of series and parallel combinations that can be formed grows exponentially with the number of resistors, n. For large n the size of the set has been found by numerical techniques to be approximately 2.53 n and analytically strict bounds are given by a Farey sequence of Fibonacci numbers. [1]

  3. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    2 Calculations. Toggle Calculations subsection. 2.1 Impedance. ... Another method of determining the series impedance of a real transformer is the short-circuit test.

  4. Quarter-wave impedance transformer - Wikipedia

    en.wikipedia.org/wiki/Quarter-wave_impedance...

    The quarter wave transformer is an alternative to a stub; but, whereas a stub is terminated in a short (or open) circuit and the length is chosen so as to produce the required impedance transformation, the λ/4 transformer is in series with the load and its length and characteristic impedance are designed to produce the required impedance ...

  5. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  6. Electrical impedance - Wikipedia

    en.wikipedia.org/wiki/Electrical_impedance

    In electrical engineering, impedance is the opposition to alternating current presented by the combined effect of resistance and reactance in a circuit. [1]Quantitatively, the impedance of a two-terminal circuit element is the ratio of the complex representation of the sinusoidal voltage between its terminals, to the complex representation of the current flowing through it. [2]

  7. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  8. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    To match the impedances, both cables must be connected to a matching transformer with a turns ratio of 2:1. In this example, the 300-ohm line is connected to the transformer side with more turns; the 75-ohm cable is connected to the transformer side with fewer turns. The formula for calculating the transformer turns ratio for this example is:

  9. Impedance parameters - Wikipedia

    en.wikipedia.org/wiki/Impedance_parameters

    Z-parameters are also known as open-circuit impedance parameters as they are calculated under open circuit conditions. i.e., I x =0, where x=1,2 refer to input and output currents flowing through the ports (of a two-port network in this case) respectively.

  1. Ad

    related to: transformer impedance calculation formula for series 1