Search results
Results from the WOW.Com Content Network
An important basic value, which is not registered in the table, is the saturated vapor pressure at the triple point of water. The internationally accepted value according to measurements of Guildner, Johnson and Jones (1976) amounts to: P w (t tp = 0.01 °C) = 611.657 Pa ± 0.010 Pa at (1 − α) = 99%
The saturation vapor density (SVD) is the maximum density of water vapor in air at a given temperature. [1] The concept is related to saturation vapor pressure (SVP). It can be used to calculate exact quantity of water vapor in the air from a relative humidity (RH = % local air humidity measured / local total air humidity possible ) Given an RH percentage, the density of water in the air is ...
Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate
The boiling point of water is the temperature at which the saturated vapor pressure equals the ambient pressure. Water supercooled below its normal freezing point has a higher vapor pressure than that of ice at the same temperature and is, thus, unstable. Calculations of the (saturation) vapor pressure of water are commonly used in meteorology.
A saturated gas or one with 100% relative humidity is when the vapor pressure of water in the air is at equilibrium with vapor pressure due to (liquid) water; water (or ice, if cool enough) will fail to lose mass through evaporation when exposed to saturated air. Because the amount of water vapor in the air is small, relative humidity, the ...
using Plots # Saturated water vapor pressure [Pa] # See Ham, 2005. Useful Equations and Tables in Micrometeorology function water_vapor_saturated_pressure (Ta, P) Ta = Ta-273.15 es = (1.0007 + (3.46e-5 * (P / 1e3))) * 0.61121 * exp ((17.502 * Ta) / (Ta + 240.97)) * 1e3 return es end function water_vapor_density (e, Tair) Rs_v = 461.5 # J/(kg.K) specific gas constant for water vapor ρv = e ...
A Assuming an altitude of 194 metres above mean sea level (the worldwide median altitude of human habitation), an indoor temperature of 23 °C, a dewpoint of 9 °C (40.85% relative humidity), and 760 mmHg sea level–corrected barometric pressure (molar water vapor content = 1.16%). B Calculated values *Derived data by calculation.
The saturation with respect to water cannot be measured much below –50 °C, so manufacturers should use one of the following expressions for calculating saturation vapour pressure relative to water at the lowest temperatures – Wexler (1976, 1977), [1] [2] reported by Flatau et al. (1992)., [3] Hyland and Wexler (1983) or Sonntag (1994 ...