Ad
related to: eto sterilization validation protocol guidelines
Search results
Results from the WOW.Com Content Network
ISO 11737 Sterilization of medical devices – Microbiological methods ISO 11737-1:2006 Part 1: Determination of a population of microorganisms on products; ISO 11737-2:2009 Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process; ISO/IEC 11756:1999 Information technology - Programming ...
The ISO 10993 set entails a series of standards for evaluating the biocompatibility of medical devices to manage biological risk. These documents were preceded by the Tripartite agreement and is a part of the international harmonisation of the safe use evaluation of medical devices. [1]
Ethylene oxide treatment is the most common chemical sterilization method, used for approximately 70% of total sterilizations, and for over 50% of all disposable medical devices. [ 26 ] [ 27 ] Ethylene oxide treatment is generally carried out between 30 and 60 °C (86 and 140 °F) with relative humidity above 30% and a gas concentration between ...
Sterile dental instruments from hospital central supply (barcoded label indicating sterilization date, expiry date and contents). The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization ...
In microbiology, in the context of a sterilization procedure, the D-value or decimal reduction time (or decimal reduction dose) is the time (or dose of an antimicrobial drug) required, at a given condition (e.g. temperature) or set of conditions, to achieve a one-log reduction, that is, to kill 90% of relevant microorganisms. [1]
Validation is a requirement of food, drug and pharmaceutical regulating agencies such as the US FDA and their good manufacturing practices guidelines. Since a wide variety of procedures, processes, and activities need to be validated, the field of validation is divided into a number of subsections including the following:
Verification is intended to check that a product, service, or system meets a set of design specifications. [6] [7] In the development phase, verification procedures involve performing special tests to model or simulate a portion, or the entirety, of a product, service, or system, then performing a review or analysis of the modeling results.
The aim of bioburden testing is to measure the total number of viable micro-organisms (total microbial count) on a medical device prior to its final sterilization before implantation or use. [ 2 ] 21 C.F.R. 211.110 (a)(6) states that bioburden in-process testing must be conducted pursuant to written procedures during the manufacturing process ...
Ad
related to: eto sterilization validation protocol guidelines