Search results
Results from the WOW.Com Content Network
Capasitor-start single-phase motor circuit diagram: Image title: A circuit diagram of a motor with LC circuit with capacitor embedded. Source: Energy-Efficient Electric Motors, Revised and Expanded, Ali Emadi, October 3, 2018, ISBN: 9781351836678: Width: 100%: Height: 100%
Now, if this motor is fed with current of 2 A and assuming that back-EMF is exactly 2 V, it is rotating at 7200 rpm and the mechanical power is 4 W, and the force on rotor is = N or 0.0053 N. The torque on shaft is 0.0053 N⋅m at 2 A because of the assumed radius of the rotor (exactly 1 m).
A single-phase supply connected to an alternating current electric motor does not produce a rotating magnetic field; single-phase motors need additional circuits for starting (capacitor start motor), and such motors are uncommon above 10 kW in rating.
There are three basic types of small induction motors: split-phase single-phase, shaded-pole single-phase, and polyphase. In two-pole single-phase motors, the torque goes to zero at 100% slip (zero speed), so these require alterations to the stator such as shaded-poles to provide starting torque. A single phase induction motor requires separate ...
English: Diagram of revolving-field single phase generator with four poles. As the rotor turns, the lines of force at fours poles are cut by the coils inducing current. The output from four coils are "in phase". The direction of current changes to the opposite side every 90 degrees of the rotation.
A shaded-pole motor is a motor, in which the auxiliary winding is composed of a copper ring or bar surrounding a portion of each pole to produce a weakly rotating magnetic field. [2] When single phase AC supply is applied to the stator winding, due to shading provided to the poles, a rotating magnetic field is generated.
The universal motor is very similar to a DC series motor in construction, but is modified slightly to allow the motor to operate properly on AC power. This type of electric motor can operate well on AC because the current in both the field coils and the armature (and the resultant magnetic fields) will alternate (reverse polarity) synchronously ...
For certain types of electric motors or generators to function, the coils of the rotor must be connected to complete an electrical circuit. Originally this was accomplished by affixing a copper or brass commutator or 'slip ring' to the shaft, with springs pressing braided copper wire 'brushes' onto the slip rings or commutator which conduct the current.