enow.com Web Search

  1. Ad

    related to: analytical balance calibration procedure as per usp section 7 form
    • Our Services

      Comprehensive Calibration Services

      Full service calibration

    • Request Quote

      Get a free quote

      Equipment service quote for free

Search results

  1. Results from the WOW.Com Content Network
  2. Gravimetric analysis - Wikipedia

    en.wikipedia.org/wiki/Gravimetric_analysis

    Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte (the ion being analyzed) based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative ...

  3. Analytical balance - Wikipedia

    en.wikipedia.org/wiki/Analytical_balance

    An analytical balance (or chemical balance) is a class of balance designed to measure small mass in the sub-milligram range. The measuring pan of an analytical balance (0.1 mg resolution or better) is inside a transparent enclosure with doors so that dust does not collect and so any air currents in the room do not affect the balance's operation.

  4. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  5. Evans balance - Wikipedia

    en.wikipedia.org/wiki/Evans_balance

    An Evans balance, also known as a Johnson Matthey magnetic susceptibility balance, is a scientific instrument used to measure the magnetic susceptibility of solids and liquids. [ 1 ] [ 2 ] Magnetic susceptibility quantifies the extent to which a material becomes magnetized in an applied magnetic field .

  6. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    In NMR spectroscopy, e.g. of the nuclei 1 H, 13 C and 29 Si, frequencies depend on the magnetic field, which is not the same across all experiments. Therefore, frequencies are reported as relative differences to tetramethylsilane (TMS), an internal standard that George Tiers proposed in 1958 and that the International Union of Pure and Applied Chemistry has since endorsed.

  7. Inductively coupled plasma mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Inductively_coupled_plasma...

    Actual analytical procedure takes some time; after that time the instrument can be switched to work on the next sample. Series of such sample measurements requires the instrument to have plasma ignited, meanwhile a number of technical parameters has to be stable in order for the results obtained to have feasibly accurate and precise interpretation.

  8. United States Pharmacopeia - Wikipedia

    en.wikipedia.org/wiki/United_States_Pharmacopeia

    The USP is published in a combined volume with the National Formulary (a formulary) as the USP-NF. [2] If a drug ingredient or drug product has an applicable USP quality standard (in the form of a USP-NF monograph), it must conform in order to use the designation "USP" or "NF".

  9. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    Validation of analytical procedures is imperative in demonstrating that a drug substance is suitable for a particular purpose. [5] Common validation characteristics include: accuracy, precision (repeatability and intermediate precision), specificity, detection limit, quantitation limit, linearity, range, and robustness.

  1. Ad

    related to: analytical balance calibration procedure as per usp section 7 form