enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Pipe network analysis - Wikipedia

    en.wikipedia.org/wiki/Pipe_network_analysis

    In fluid dynamics, pipe network analysis is the analysis of the fluid flow through a hydraulics network, containing several or many interconnected branches. The aim is to determine the flow rates and pressure drops in the individual sections of the network. This is a common problem in hydraulic design.

  3. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    Hydronics (from Ancient Greek hydro- 'water') is the use of liquid water or gaseous water or a water solution (usually glycol with water) as a heat-transfer medium in heating and cooling systems. [1] [2] The name differentiates such systems from oil and refrigerant systems.

  4. Air lock - Wikipedia

    en.wikipedia.org/wiki/Air_lock

    Air lock problems often occur when one is trying to recommission a system after it has been deliberately (for servicing) or accidentally emptied. Take, for example, a central heating system using a circulating pump to pump water through radiators. When filling such a system, air is trapped in the radiators. This air has to be vented using screw ...

  5. Hydrostatic loop - Wikipedia

    en.wikipedia.org/wiki/Hydrostatic_loop

    A hydrostatic loop, though not often used in plumbing practice, is an arrangement of pipes formed into a vertical loop to prevent backflow of water within the plumbing potable water system. Since a siphon has a maximum height that it can work (about 33 feet), a hydrostatic loop is built higher than 33 feet. There are several ways to prevent ...

  6. Uniform Mechanical Code - Wikipedia

    en.wikipedia.org/wiki/Uniform_Mechanical_Code

    The Uniform Mechanical Code (UMC) is a model code developed by the International Association of Plumbing and Mechanical Officials to govern the installation, inspection and maintenance of HVAC (heating, ventilating and air-conditioning) and refrigeration systems. It is designated as an American National Standard.

  7. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    Steam hammer can occur in steam systems when some of the steam condenses into water in a horizontal section of the piping. The steam forcing the liquid water along the pipe forms a "slug" which impacts a valve of pipe fitting, creating a loud hammering noise and high pressure. Vacuum caused by condensation from thermal shock can also cause a ...

  8. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Hydronic fan coil units can be generally divided into two types: Two-pipe fan coil units or four-pipe fan coil units. Two-pipe fan coil units have one supply and one return pipe. The supply pipe supplies either cold or hot water to the unit depending on the time of year. Four-pipe fan coil units have two supply pipes and two return pipes.

  9. Zone valve - Wikipedia

    en.wikipedia.org/wiki/Zone_valve

    [2] No inherent redundancy for the pump. A zone-valved system is dependent upon a single circulator pump. If it fails, the system becomes completely inoperable. The system can be harder to design, requiring both "SPDT" thermostats or relays and the ability of the system to withstand the fault condition whereby all zone valves are closed ...