Search results
Results from the WOW.Com Content Network
Maximum Demand Indicator (MDI) is an instrument for measuring the maximum amount [clarification needed] of electrical energy required by a specific consumer during a given period of time. [1] MDI instruments record the base load requirement of electrical energy .
At this time there is a combination of office, domestic demand and at some times of the year, the fall of darkness. [2] Some utilities will charge customers based on their individual peak demand. The highest demand during each month or even a single 15 to 30 minute period of highest use in the previous year may be used to calculate charges. [3]
peak demand = 436 kW; use = 57 200 kWh; number of days in billing cycle = 30 d; Hence: load factor = ( [ 57 200 kWh / {30 d × 24 h/d} ] / 436 kW) × 100% = 18.22%; It can be derived from the load profile of the specific device or system of devices. Its value is always less than one because maximum demand is never lower than average demand ...
The demand factor is always less than or equal to one. As the amount of demand is a time dependent quantity so is the demand factor. ... drew a maximum of 3,000 W in ...
The unofficial term diversity, as distinguished from diversity factor, refers to the percent of time available that a machine, piece of equipment, or facility has its maximum or nominal load or demand; a 70% diversity means that the device in question operates at its nominal or maximum load level 70% of the time that it is connected and turned on.
Cable sizing must therefore consider maximum demand, voltage drop over the cable, and current-carrying capacity. Voltage drop is usually the main factor considered, but current-carrying capacity is as important when considering short, high-current runs such as between a battery bank and inverter.
In a power system, a load curve or load profile is a chart illustrating the variation in demand/electrical load over a specific time. Generation companies use this information to plan how much power they will need to generate at any given time. A load duration curve is similar to a load curve. The information is the same but is presented in a ...
MSP kWh is the amount of electricity consumed at the 'meter supply point', which is the customer's meter. GSP kWh is obtained by multiplying the MSP kWh by the Line Loss Factor (LLF, a figure > 1) to include the amount of electricity lost when it is conducted through the distribution network, from the 'grid supply point' to the customer's meter.