Search results
Results from the WOW.Com Content Network
To reduce this loss these antennas often use a conductive copper ground screen under the antenna connected to the buried ground wires, either lying on the ground or elevated a few feet, to shield the ground from the electric field. In a few cases where rocky or sandy soil has too high a resistance for a buried ground, a counterpoise is used. [11]
A ring ground is typically constructed from a fairly large wire that is buried at least a few feet underground. The ring ground will usually encircle the entire building that it is trying to protect. The ring ground is used as the base of the entire building's ground system, and all components of the building's ground system, including the ...
Above-ground lines cost around $10 per 1-foot (0.30 m) and underground lines cost in the range of $20 to $40 per 1-foot (0.30 m). [10] In highly urbanized areas, the cost of underground transmission can be 10–14 times as expensive as overhead. [11] However, these calculations may neglect the cost of power interruptions.
A utility tunnel, utility corridor, or utilidor is a passage built underground or above ground to carry utility lines such as electricity, steam, water supply pipes, and sewer pipes. Communications utilities like fiber optics , cable television , and telephone cables are also sometimes carried.
Utility poles were first used in the mid-19th century in America with telegraph systems, starting with Samuel Morse, who attempted to bury a line between Baltimore and Washington, D.C., but moved it above ground when this system proved faulty. Today, underground distribution lines are increasingly used as an alternative to utility poles in ...
Consumers Energy received approval on Friday, March 1, 2024, to bury around 10 miles of electric lines underground, something the company says will improve reliability for customers as the power ...
A grounded wire is sometimes strung along the tops of the towers to provide lightning protection. An optical ground wire is a more advanced version with embedded optical fibers for communication. Overhead wire markers can be mounted on the ground wire to meet International Civil Aviation Organization recommendations. [6]
Cross-section of direct buried cable. Direct-buried cable (DBC) is a kind of communications or transmissions electrical cable which is especially designed to be buried under the ground without any other cover, sheath, or duct to protect it. [1] Most direct-buried cable is built to specific tolerances to heat, moisture, conductivity, and soil ...