When identifying the unit/firefighter alarm designation, the initial dispatch is referred to as a "first alarm" and is typically the largest. Subsequent alarms are calls for additional units, usually because the fire has grown and additional resources are needed to combat it, or because the incident is persisting long enough that firefighters on scene need to be relieved.
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.
The majority of guidance available for design of heat and smoke building vents installed in buildings is restricted to nonsprinklered, single-story buildings. [4] This is partly a historical consequence of the installation of heat and smoke vents following the August 1953 General Motors, Livonia, MI major fire in a nonsprinklered manufacturing facility which effectively stopped the production ...
The bottom line of the National Fire Danger Rating System in the day-to-day operation of a fire prevention and suppression program is the staffing class. The staffing class is sometimes referred to as the action class, adjective class, precaution class, preparedness class, or the Industrial Fire Precaution Level (IFPL). [2]
Alert or Alarm - Raise the alarm by triggering a fire alarm. Alert nearby persons to gain assistance in fighting the fire or alerting other people. Alert emergency services, site security and other emergency contacts as necessary. Confine or Contain - Contain the spread of the fire by closing nearby doors and windows if it is safe to do so. The ...
An aspirating smoke detector (ASD) is a system used in active fire protection, consisting of a central detection unit which draws air through a network of pipes to detect smoke. [1] The sampling chamber is based on a nephelometer that detects the presence of smoke particles suspended in air by detecting the light scattered by them in the ...
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.