The International Temperature Scale of 1990 (ITS-90) is an equipment calibration standard specified by the International Committee of Weights and Measures (CIPM) for making measurements on the Kelvin and Celsius temperature scales. It is an approximation of thermodynamic temperature that facilitates the comparability and compatibility of ...
However, a common temperature and pressure in use by NIST for thermodynamic experiments is 298.15 K (25 °C, 77 °F) and 1 bar (14.5038 psi, 100 kPa). [4] [5] NIST also uses 15 °C (288.15 K, 59 °F) for the temperature compensation of refined petroleum products, despite noting that these two values are not exactly consistent with each other.
E2758-10 Standard Guide for Selection and Use of Wideband, Low Temperature Infrared Thermometers. E2847-11 Standard Practice for Calibration and Accuracy Verification of Wideband Infrared Thermometers
The Joint Committee for Guides in Metrology (JCGM) is a committee which created and maintains two metrology guides: Guide to the expression of uncertainty in measurement (GUM) [54] and International vocabulary of metrology – basic and general concepts and associated terms (VIM). [33] The JCGM is a collaboration of eight partner organisations ...
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
A thermometer has two important elements: (1) a temperature sensor (e.g. the bulb of a mercury-in-glass thermometer or the pyrometric sensor in an infrared thermometer) in which some change occurs with a change in temperature; and (2) some means of converting this change into a numerical value (e.g. the visible scale that is marked on a mercury ...
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories is the main standard used by testing and calibration laboratories. In most countries, ISO/IEC 17025 is the standard for which most labs must hold accreditation in order to be deemed technically competent.
NIST had an operating budget for fiscal year 2007 (October 1, 2006 – September 30, 2007) of about $843.3 million. NIST's 2009 budget was $992 million, and it also received $610 million as part of the American Recovery and Reinvestment Act. [18] NIST employs about 2,900 scientists, engineers, technicians, and support and administrative personnel.