  2. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...

  3. Potentiometric titration - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_titration

    Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as

  4. Ion-selective electrode - Wikipedia

    en.wikipedia.org/wiki/Ion-selective_electrode

    An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .

  5. Reference electrode - Wikipedia

    en.wikipedia.org/wiki/Reference_electrode

    A reference electrode is an electrode that has a stable and well-known electrode potential. The overall chemical reaction taking place in a cell is made up of two independent half-reactions , which describe chemical changes at the two electrodes.

  6. Potentiometric sensor - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_sensor

    Type III sensors make the electrode concept even more confusing. With respect to the design of a solid state sensor, the auxiliary phase looks as part of the electrode. But it cannot be an electrode because auxiliary phase materials are not generally good electrical conductor. In spite of this confusion, type III design offers more feasibility ...

  7. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    The design of the electrodes is the key part: These are rod-like structures usually made of glass, with a bulb containing the sensor at the bottom. The glass electrode for measuring the pH has a glass bulb specifically designed to be selective to hydrogen-ion concentration.

  8. Potentiometer (measuring instrument) - Wikipedia

    en.wikipedia.org/wiki/Potentiometer_(measuring...

    A potentiometer being calibrated and then measuring an unknown voltage. R 1 is the resistance of the entire resistance wire. The arrow head represents the moving wiper.. In this circuit, the ends of a uniform resistance wire R 1 are connected to a regulated DC supply V S for use as a voltage divider.

  9. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    A second pair of Pt electrodes is immersed in the anode solution. The detector circuit maintains a constant current between the two detector electrodes during titration. Prior to the equivalence point, the solution contains I − but little I 2. At the equivalence point, excess I 2 appears and an abrupt voltage drop marks the end point.