Search results
Results from the WOW.Com Content Network
Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)
This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units.
The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]
The effectiveness of bulk insulation is commonly evaluated by its R-value, of which there are two – metric (SI) (with unit K⋅W −1 ⋅m 2) and US customary (with unit °F⋅ft 2 ⋅h/BTU), the former being 0.176 times the latter numerically, or the reciprocal quantity the thermal conductivity or U-value W⋅K −1 ⋅m −2.
Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...
Sapphire values are taken from Kingery, W.D. and Norton, F.H., USAEC Rept. NYO-6447, 1–14, 1955, TPRC II pages 94, 96, curve 19 ref. 72 page 1160. [32] Errata: The numbered references in the NSRDS-NBS-8 pdf are found near the end of the TPRC Data Book Volume 2 and not somewhere in Volume 3 like it says. [32] Aluminium oxide, porous 22% ...
Quadruple glazed office building in Oslo, Norway, U-value 0.29 W/m 2 K, R-value 20. The insulation effectiveness can be expressed as an R-value or RSI value. The higher the value, the greater is its resistance to heat transfer. A standard IGU consisting of clear uncoated panes of glass (or lights) with air in the cavity between the lights ...